- [Automatic Transfer Switch] -- The automatic power transfer switch can be operated automatically or manually, switching in milliseconds without power interruption - [Continuous Power Supply] -- The automatic transfer switch works by immediately activating the backup power supply when the normal power supply fails. When the normal power supply is activated, it automatically switches back to the normal power supply, ensuring a continuous and reliable power supply - [Product Specifications] -- Electrical Class: PC Class. Number of Poles: 2P. Rated Operating Current: 100A. Rated Operating Voltage: 110V. Rated Frequency: 50Hz/60Hz - [Superior Materials & Easy Installation] ? This transfer switch is made of high-quality PC flame-retardant material and silver, offering excellent insulation and high-temperature resistance. Standard 35mm DIN rail mounting, also suitable for PZ30 distribution boxes - [Wide Applications] -- Suitable for various locations requiring continuous power supply, providing short-circuit protection, overload protection, phase loss protection, and undervoltage protection for homes, shopping malls, factories, laboratories, and farms

Product description

Spec:

Item Type: Dual Power Automatic Transfer Switch

Material: PC, silver

Switch Type: Secondary power distribution

Rated Current: 100A

Rated Voltage: 110VAC

Insulation Voltage: 690VAC

Rated Frequency: 50Hz 60Hz

Electrical Grade: PC grade isolation type

Rated Impact Withstand Voltage: 8KV

Touch Time: Operation Conversion Time: Return Time: Closing Time:

Check the integrity of the ATS before installation, turn the ATS on or off with the operating handle, check the flexibility of the drive and test the generation and disconnection conditions for each stage of load for normal and standby power.

1.The installation site must have a maximum temperature of 40℃, a minimum of -5℃, and a 24-hour average not exceeding 35℃.

2.The installation altitude must not exceed 2000m.

3.At 40℃, relative humidity should remain below 50%; at -5℃, it may be higher; for example, at 25℃, it can reach 90%. Special measures must be taken to address potential condensation due to temperature fluctuations.